Everpure Water System CB20 124E User Manual

Part Number EV9100-51  
INSTALLATION AND OPERATING INSTRUCTIONS  
CB20-124E FILTRATION SYSTEM  
SYSTEM INSTALLATIONS  
NOTE: Always use a good grade of pipe sealant or teflon tape on  
connections.  
GENERAL PRECAUTIONS  
Maximum Pressure: 20-100 psi non-stock (1.4-6.9 bar)  
Temperature: 35-100°F (2-38°C)  
®
1. Reduce product weight by removing bowl from header assembly  
Install On Cold Water Lines Only  
before mounting unit.  
Installation By a Certified Installer Is Recommended  
2. Determine installation location using head assembly.  
3. Assemble By-Pass, if using and install to head.  
4. Install system brackets. Mount system.  
Housing Inlet & Outlet: 3/4"  
Rated service flow: 5 gpm (19 Lpm)  
Do not install where unit is exposed to direct sunlight.  
5. Turn off water and power supply to all beverage equipment and  
Allow a minimum of 4" clearance under the filter to facilitate cartridge  
change. Make certain that the installation complies with all state and  
local laws and regulations.  
icemaker.  
6. Connect cartridge system to feed water supply, beverage sys-  
tems, and icemaker.  
WARNING: This filter must be protected from freezing. Failure to do  
so may result in cracking of the filter and water leakage.  
7. Sanitize filter bowls using dilute (0.5%) household bleach solution,  
Diversol™ or equivalent.  
8. Handle cartridges by plastic wrap to minimize contact.  
CB20-124E FILTRATION SYSTEM  
9. Lubricate “O-rings” with silicone lubricant and secure to system  
head. Hand tighten.  
10. Cartridge Change and Flush Procedure:  
Insert the fresh cartridge into the clean bowl and screw the bowl  
into the head, hand tight only. Turn on water and flush cartridge  
for 15 minutes.  
1
7 ⁄4  
"
3/4" Outlet  
Connection  
to Equipment  
3/4" Inlet  
Connection  
from Supply  
11. Close flushing valve and inspect for leaks.  
12. Turn power to beverage equipment and icemaker back on.  
13. Clean up and give final inspection.  
14. Obtain Manager sign-off on work confirmation form.  
3
25 ⁄4  
"
REPLACEMENT CARTRIDGE  
CC1E Carbon Filter  
Replace cartridge when capacity is reached or pressure drops below  
15 psi, but at least every 6 months.  
1. Turn power off to beverage equipment.  
2. Turn water off to CB20-124E system.  
3. Unscrew bowl assembly from header, remove exhausted cartridge  
and discard. CAUTION: Bowl is heavy with water.  
4. Unwrap new cartridge and place in bowl. Screw bowl into appro-  
Mounting Depth: 8.5"  
Operating Weight: 30 lbs.  
Allow a minimum of 4" clearance under the  
filter to facilitate cartridge change.  
priate head on system.  
5. Turn on water and flush cartridge for 15 minutes.  
For assistance or to find the nearest dealer for replacement parts call:  
Everpure Customer Service 1-800-323-7873  
Everpure Technical Service 1-800-942-1153  
System Tested and Certified by NSF International against NSF/ANSI  
Standard 42 for the aesthetic reduction of Chlorine Taste and Odor and  
Chloramine Reduction.  
 

Code Alarm Remote Starter CA 6550 User Manual
Craftsman Lawn Mower 486248473 User Manual
Craftsman Tiller 917 299751 User Manual
Crate Amplifiers Stereo Amplifier G120C User Manual
Curtis Flat Panel Television LCD3213A User Manual
Delta Electronics Power Supply E E 18 User Manual
Dimension One Spas Hot Tub Triad II User Manual
Dyna Glo Electric Heater RMC KFA65TDLX RMC KFA120TDLX RMC KFA170TDLX User Manual
Fisher Paykel Oven OB60SL9DEX User Manual
Generac Power Systems Portable Generator 5747 0 User Manual