MIL-170TRM
10BASE-FL to 10BASE-T
Media Converter for Digi's
Media Conversion System
Thumbscrews
TP
FX
10BASE-FL
ACT ACT
MDI-X MDI
TP
FX
TX
RX
MIL-
170TRM
LINK LINK
10BASE-T
Installation Guide
This guide includes the following:
“Introduction” on page 2
“Features” on page 2
“Installation” on page 2
“Indicators” on page 4
“Specifications” on page 4
Doc #: 90000096 Rev. A
Install Guide
MDI-X/MDI Switch
The MDI-X/ MDI switch allows for quick configuration of the 10BASE-T port.
Cables used when the switch is in the MDI-X position (the “left” position):
•
For a hub/ repeater, use a swap cable (pins are connected 1 to 3, 2 to 6, 3 to 1,
and 6 to 2)
•
For a workstation/ PC, use a straight-through cable (pins are connected 1 to 1,
2 to 2, 3 to 3, and 6 to 6)
4
3
2
1
4-pin DIP Switch
LEDs
(4 total)
RJ-45 Female
Connector
MDI-X/MDI
Switch
ST-Type
Connectors
Fig u re 1 .In sid e o f th e MIL-1 7 0 TRM
Cables used when the switch is in the MDI position (the “right” position):
•
For a hub/ repeater, use a straight-through cable (pins are connected 1 to 1, 2 to
2, 3 to 3, and 6 to 6)
•
For a workstation/ PC port, use a swap cable (pins are connected 1 to 3, 2 to 6,
3 to 1, and 6 to 2)
Link Sentry Configuration
The Link Sentry feature on the MIL-170TRM is configured through a 4-position
DIP switch (refer to Figure 1). Default setting for the DIP switches: All switches
are in the “up” position.
Link Sentry allows users to add new management tools to the network. When
enabled, it monitors the selected receiver port and, if the Link test signal is not
seen, the unit will stop sending a signal through the selected transmit port.
Model: MIL-170TRM
3
Install Guide
The following table shows which Link Sentry feature is enabled:
Table 1: Link Sentry Features
Switch
Losing Link on RX of
Stop sending Link on TX of
1 (down)
2 (down)
3 (down)
4 (down)
Fiber port
UTP port
UTP port
Fiber port
Fiber port
UTP port
Fiber port
UTP port
Note: For two MIL-170s used back-to-back and UTP-to-UTP, all DIP switches must be enabled
(in the “down” position) on the first MIL-170. On the second MIL-170, enable switches 1
and 4 (in the “down” position).
Default setting for Link Sentry: All switches set in the “up” position (disabled). When using
the SNMP module to control the Link Sentry feature, leave the switches in the default
mode (“up”).
Indicators
There are four LEDs, including:
TP/ACT: Receiving packets from the 10BASE-T port
TP/LINK: There is an active connection on the 10BASE-T port
FX/LINK: There is an active connection on the 10BASE-FL port
FX/ACT: Receiving packets from the 10BASE-FL port
Specifications
RJ-45: MDI
•
•
•
•
Pin 1 = Transmit Data +
Pin 2 = Transmit Data -
Pin 3 = Receive Data +
Pin 6 = Receive Data -
RJ-45: MDI-X
•
•
•
•
Pin 1 = Receive Data +
Pin 2 = Receive Data -
Pin 3 = Transmit Data +
Pin 6 = Transmit Data -
Model: MIL-170TRM
4
Install Guide
4
5
3
6
7
2
8
1
Fig u re 2 .RJ-4 5 Pin o u ts
Fiber Specifications: ST connector
•
•
•
•
1300 nm single-mode fiber
8 or 9/ 125 µm single-mode fiber
Launch power: -19 dBm
Receive sensitivity: -36 dBm
Operating Conditions
Table 2: Recommended Operation Conditions
Parameters
Minimum
Maximum
Operating Temperature
Humidity: Non-condensing
Signal Output Load
Supply Voltage
+5° C
+50° C
95%
10%
35 ohm
4.75 V
75 ohm
5.25 V
Model: MIL-170TRM
5
Legal Declaration
Regulatory Approvals
•
•
•
•
•
FCC Class A
UL 1950
CSA 22 No. 950
EN60950
CE
– EN55022 Class B
– EN50082-1
Canadian EMI Notice
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
European Notice
Products with the CE Marking comply with both the EMC Directive (89/ 336/ EEC) and the Low Voltage
Directive (73/ 23/ EEC) issued by the commission of the European Community. Compliance with these
directives implies conformity to the following European Norms:
•
•
•
EN55022 (CISPR 22) - Radio Frequency Interference
EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity
EN60950 (IEC950) - Product Safety
Five-Year Limited Warranty
Digi International warrants to the original consumer or purchaser that each of its
products, and all components thereof, will be free from defects in material and/ or
workmanship for a period of five years from the original factory shipment date. Any
warranty hereunder is extended to the original consumer or purchaser and is not
assignable.
Digi makes no express or implied warranties including, but not limited to, any implied
warranty of merchantability or fitness for a particular purpose, except as expressly set
forth in this warranty. In no event shall Digi be liable for incidental or consequential
damages, costs, or expenses arising out of or in connection with the performance of the
product delivered hereunder. Digi will in no case cover damages arising out of the
product being used in a negligent fashion or manner.
To Contact Digi
For prompt response when calling for service information, have the following information ready:
•
•
•
Product serial number and rev.
Date of purchase
Vendor or place of purchase
Reach Digi Technical Support at 408/ 744-2751
Or E-mail at “sun-tech@dgii.com”
Address: 1299 Orleans Drive
Sunnyvale, CA 94089
408/ 744-2775
408/ 744-2793
Voice:
Fax:
E-mail: info@dgii.com
Doc #: 90000096 Rev. A
|