Delfield Refrigerator SAR1N S User Manual

®
Project __________________________________  
Item ____________________________________  
Quantity ________________________________  
CSI Section 11400  
Delfield  
Approved _______________________________  
Date ____________________________________  
Specification Line®  
Self-Contained Solid Door Narrow Reach-In Refrigerator  
Models  
One section Two section  
SSR1N-S  
SSR2N-S  
Stainless exterior and interior full door  
SSR1N-SH  
SAR1N-S  
SAR1N-SH  
SMR1N-S  
SMR1N-SH  
SSR2N-SH  
SAR2N-S  
SAR2N-SH  
SMR2N-S  
SMR2N-SH  
Stainless exterior and interior half door  
Stainless exterior and aluminum interior full door  
Stainless exterior and aluminum interior half door  
Stainless front aluminum exterior and interior full door  
Stainless front aluminum exterior and interior half door  
Standard Features  
Options &  
Accessories  
Stainless steel interior and exterior (SS)  
Stainless steel exterior, aluminum interior (SA)  
Aluminum interior and exterior, stainless front (SM)  
Built in door locks with heavy duty strikes  
Recessed metal door handle  
Security (prison) package  
6polyurethane casters  
Door field rehingability  
Stainless steel interior door liner  
Additional shelves  
Pressure relief valve is standard to prevent door  
vapor lock  
Exterior digital thermometer with high/low tem-  
perature alarm  
Tray slides  
Stainless steel back  
Easy to use electronic control  
Easy access “flip upshroud  
Three wire shelves per section - SA/SS standard with  
chrome plated shelves and SM standard with epoxy  
coated shelves  
Laminate on front, sides and back  
Bottom mount electrical  
Stainless steel banking strip  
Heat shield end  
Stainless steel kick plate  
Laminate kick plate  
4stainless steel utility base  
230-50-1 electrical  
220-60-1 electrical  
Tough ABS interior door liners  
10attached cord and plug  
6adjustable stainless steel legs  
Stainless steel breaker strips  
High density foamed in place environmentally  
friendly, Kyoto Protocol Compliant, Non ODP (Ozone  
Depletion Potential), Non GWP (Global Warming  
Potential) polyurethane keeps energy costs low  
Energy savings door heater switch  
Two year parts & labor warranty  
SSR2N-SH  
Five year compressor warranty  
Specifications  
Exterior: SS and SA models shall have corrosion resistant stainless  
steel exterior cabinet sides, front and shroud. SM models shall have  
corrosion resistant aluminum on exterior cabinet sides and will have  
stainless front and shroud. All units shall have the upper shroud  
hinged with a gas assist stay open feature to provide easy access to  
the refrigeration system.  
can be removed from the cabinet without the use of tools. Metal  
door handle shall be recessed into the door for easy grip without  
impacting aisle space. Keyed door lock is mounted in the door next  
to the handle. Lock engages into a heavy duty strike mounted to the  
cabinet face. Door gaskets are magnetic and mount to the door snap-  
ping in place and are removable without tools.  
Interior: Cabinet interior shall be corrosion resistant stainless steel  
(SS models) or heavy gauge aluminum (SA and SM models). Bottom  
and top surfaces shall be die stamped to provide radius corners and  
recessed floor. Three wire shelves are provided per section, SA/SS  
standard shelves are chrome plated, SM standard shelves are epoxy  
coated. Shelves rest on clips which are adjustable on 1increments  
on stainless steel pilasters affixed to the cabinet interior. Pilasters are  
removable without tools for cleaning. Mounted to the interior ceiling,  
the interior incandescent light is controlled automatically through  
a switch mounted in the hinge assembly to protect against break-  
age. Door openings are protected with heavy gauge stainless steel  
breaker strips. An air duct shall be mounted to the ceiling assuring  
low velocity, even air movement throughout the cabinet interior.  
Refrigeration system: All components are mounted to the exterior  
of the cabinet ceiling, outside the food zone and are assembled  
as one piece and can be removed as one piece. Environmentally  
friendly R404A refrigerant is used. The system has the capability of  
maintaining between 27ºF and 40ºF in heavy use food service opera-  
tions. Refrigerant is metered using a highly responsive thermostatic  
expansion valve. System is controlled using Delfield’s ACT-Advanced  
Control Technology electronic temperature control, which provides  
improved pull down times, reduces compressor cycling and longer  
compressor life with lower energy consumption.  
Control system uses adaptive defrost to assure evaporator coil is free  
of ice and is operating at optimum efficiency. Evaporator condensate  
is eliminated using an energy efficient hot gas system.  
Doors: Exterior shall be corrosion resistant stainless steel. Interior  
liner shall be resilient high impact ABS material formed to protrude  
beyond the door gasket to protect the gasket from tearing. Each  
door has two edge mount, self closing, cam lift style hinges. Doors  
Electrical: Standard electrical connections shall be 115V, 60 Hz single  
phase. A 10cord and plug is supplied and attached to a junction box  
mounted on the exterior top of the cabinet.  
980 S. Isabella Rd.  
Mt. Pleasant, Michigan 48858  
Phone: 800-733-8948 or 989-773-7981  
Fax: 800-669-0619  
 

Cornelius Beverage Dispenser R 404A REFRIGERANT User Manual
Cub Cadet Lawn Mower 19A40002100 User Manual
Cybex International Treadmill CX 445T User Manual
Dukane Projector ImagePro 8909 User Manual
Duracell Battery Charger DL1 3N User Manual
Electro Voice Speaker System FRX+660 User Manual
Fitness Quest Home Gym 2100HR User Manual
Frigidaire Refrigerator GLHS68EE User Manual
Geemarc Telephone Petite Trac User Manual
Globalsat Technology Headphones BTA 830 User Manual